Cat® XQC 1600 Power Module * 50/60Hz SWITCHABLE UNITS FOR USE WORLDWIDE

Cat® XQC 1600 Power Module * 50/60Hz SWITCHABLE UNITS FOR USE WORLDWIDE

$0.00Price

Cat® XQC 1600 Power Module - SPECIAL 50/60Hz SWITCHABLE UNITS FOR USE WORLDWIDE - EXPORT ONLY UNIT ONLY 20 LEFT 

 

Download Brochure

 

• 50/60 Hz switchable for greater fleet utilization and versatility with neither software re-flashing, nor iron changes required

BRAND NEW  2025 & 2026 MODELS

Benefits & Features:

Worldwide Product Support

• Cat® dealers provide extensive post sale support including maintenance and repair agreements

• Supported 100% by your Cat dealer with warranty on parts and labor

• Extended Service Coverage (ESC) options available for coverage beyond the Standard Warranty period Cat® 3516C Diesel Engine

• The compact, four-cycle Cat 3516C turbocharged aftercooled (SCAC) diesel engine

• Reliable, Fuel Efficient

• Best-in-class fuel economy

• Other engine features include: electric fuel priming, individual cylinder temperature monitoring, and extended filter change intervals

• Electronic differential pressure monitoring of all filters Cat SR5 Series Generator

• Designed to match performance and output characteristics of Cat diesel engines

• Class H insulation operating at Class F temperature for extended life

• Stator winding and bearing temperature monitoring

• Coastal insulation protection and anti-condensation space heaters for extended life and increased reliability Cat EMCP 4.3 Control Panel

• Provides full engine and generator monitoring and fault protection

• Graphical display (5.5 in.) denotes text alarm/ event descriptions, set points, engine and generator monitoring, and is visible in all lighting conditions

• Simple, user-friendly interface and navigation

• 50/60 Hz toggle switch via terminal link

• Integrated Voltage Regulator (IVR) to provide precise steady state control and excellent transient response o Removes duplicate set points and wiring for simplified operation and troubleshooting o Dedicated IVR status screens in EMCP4.4 o IVR fully supported by Cat ET (Electronic Technician) service tool

• Panel mounted emergency stop switch *Does not conform to EPA/EU emissions standards Power Distribution and Paralleling Controls

• Externally-accessible,100 k AIC power distribution panel

• 3-pole, 4000A-frame (set to 3000A), electrically operated, insulated IEC Circuit Breaker (Optional 4- pole breaker)

• Externally-accessible, package mounted auto paralleling controls behind hinged door

• AGC-4 provides paralleling, load sharing, VFD control, and additional generator protection Sound-attenuated Container

• Provides 9-high stackable CSC 40-ft high-cube container for ease of transportation and protection

• Personnel doors (2 total) on both sides of the engine for service access, plus 1 additional personnel door for general access

• Double container doors on each end for ease of service

• Service door for access to primary fuel filters

• Foldable, stowable awnings on engine room air inlets also serve as shipping covers

• Hinged, sound-attenuated radiator louvers for ease of cleaning and maintenance Fuel System

• Fuel system operates on a variety of fuels

• Triple primary fuel filters with water separators, service valves, and differential pressure monitoring Reduced Environmental Impact • 110% spill containment of onboard engine fluids

• Positive crankcase fumes ventilation

• Low BSFC and Low Emissions* ratings, switchable via Cat Electronic Technician (ET) Asset Monitoring and Management

• Cat Connect PLE601 Quality

• Single Source Supplier

• Factory designed and production tested to assure customer satisfaction

• Package factory designed and production tested

• Manufactured in ISO 9001:2000 certified facility

Quantity
  • Technical Specifications

    Standard Equipment

    Cat 3516C Heavy Duty Diesel Engine

    • Turbocharged, air-to-water aftercooler

    • Electronic ADEM™ A4 engine controls Generator • 1844-frame; SR-5 generator • Double bearing, wye-connected, brushless, permanent magnet excited, form wound design • Generator mounted Cat Integrated Voltage Regulator (Cat IVR) • Stator winding and bearing temperature sensors and RTD module • Metallic mesh generator air inlet filters (washable) with differential pressure monitoring Air Filter • Air cleaner – Heavy duty element, canister type air with service indicator Cat Cooling System • Cooling package provides 49°C (120F) ambient capability (50 Hz and 60 Hz) at the IPP Rating @ 750m (2,460 ft) above sea level • Jacket water heater (9 kW, 3-phase 480 VAC) with electric pump • Energy efficient direct drive fans (4) • Variable frequency fan drive with smart fan control • Cat Extended Life Coolant (ELC) • Vertical, non-stacked radiator cores and dimpled fins to minimize clogging Starting/Charging System • Dual 24-Volt Electric Starting Motors • 24 VDC/50A battery charger with float/equalize modes and charging ammeter • Four (4) 1400 CCA,24V-Maintenance Fuel System • 946 L (250 gal) single-wall fuel tank • BS799-5 certified • Solenoid fuel fill control valve • Secondary fuel filters on engine • Fuel cooler and electric priming pump Exhaust System • Internally mounted, insulated, puck-style exhaust silencer suspended from container roof • 1.8m (6 ft) vertical discharge exhaust stack for increase site power density, stows for shipping inside container Lube Oil System • Full flow oil filters with water-cooled oil cooler (Requires API CI-4 or higher lube oil) • Oil drain lines routed to the engine rail • Includes engine-mounted oil level regulator and 114 L (30 gal) oil tank for maintaining oil pan levels in extended run applications • Oil tank can be remotely filled without shutting down the engine • Oil evacuation system for faster, cleaner oil changes Control Panel • Package-mounted EMCP 4.3 provides power metering, protective relaying, and engine and generator control and monitoring • Convenient service access for Cat service tools • Integration with the Cat Integrated Voltage Regulator (IVR) provides enhanced system monitoring • Ability to view and reset diagnostics of all controls networked on J1939 data link eliminates need for separate service tools for troubleshooting • Real-time clock allows for date and time-stamping of diagnostics and events • True RMS AC metering, 3 phase: L-L volts, L-N volts, Phase, Amps, Hz, ekW, kVA, kVAR, kWHr,% kW, PF • Graphical display with positive image, transflective LCD, adjustable white backlight/contrast • Digital indication for:– RPM – DC Volts – Oil pressure – Oil Temperature– Operating hours– Coolant Temperature • Two LED status indicators (1 red, 1 amber) • Engine cool-down timer • Engine cycle crank • Three engine control keys and status indicators (Run/Auto/Stop). • Lamp test and Alarm acknowledgement keys • Warnings/shutdowns with indicating text for:– Low oil pressure – Overspeed– High Oil Temperature – Emergency stop • Emergency stop pushbutton– Overcrank– AGC-4 • Display navigation keys including two shortcut keys for Engine Parameters or Generator Parameters LEHX0023-07 3 of 10 Cat® XQC 1600 Power Module Standard Equipment (continued) Container • Sound attenuated to 75 dB(A) (50 Hz) 81 dB(A) (60 Hz) at 7m (23 ft) • Five (5) lockable personnel doors with panic releases on each door • Interior walls and ceilings insulated with 100 mm of acoustic paneling • Side bus bar access door with external access load cable connections • Six (6) DC lights with 60-min timer located at one personnel door • Engine vibration isolators • Easy drain access to standard fluids • E-stops located on each side of the container (2) • One (1) International-style convenience receptacle located on the front of the control panel Distribution System • 3000:5 Current Transformers with secondaries wired to shorting terminal strips • Three phase, plus full rated neutral bus bars are tin-plated copper with NEMA standard 2-hole pattern for connection of customer load cables and generator cables. • Bus bars are sized for full load capacity of the generator set at 0.8 power factor. • Includes ground bus, tin-plated copper, for connection to the generator frame ground and field ground cable • Transformer provides 240 and 480 VAC for module accessories • Includes controls to de-energize jacket water heaters and generator anti-condensation heater when the engine is running • One (1) shore power connections for generator anti- condensation heater, battery charger, jacket water heater, and convenience receptacle • Solid state trip unit for overload (time overcurrent) and fault (instantaneous) overcurrent protection. LSIG is standard • Includes DC shunt trip coil activated on any monitored engine or electrical fault • Ground fault sensing/trip (Requires Optional ground CT) Power Factor Control Circuitry • Manual raise/lower voltage adjust capability and VAR/ power factor control circuitry for maintaining constant generator power factor while paralleled with the utility. Voltage and power factor adjustments are performed on the Generator Paralleling Control • Includes RFI suppression, exciter limiter, and exciter diode monitoring Protective Relaying • Generator protective relaying features:– Phase over/under voltage (Device 27/59)– Over/Under frequency (Device 81 O/U)– Reverse Power (Device 32)– Overcurrent (Device 50/51) (GCB trip unit)– Loss of Excitation (Device 40) (Cat IVR) • Package mounted AGC-4 controls provides auto paralleling, CAN-bus, Ethernet communications, PWM and Analog outputs, and legacy analog load sharing (real and reactive) • AGC-4 main display and Additional Operator Panel (AOP) secondary display • AGC-4/EMCP 4.3 protective relaying features:– 25 sync-check (AGC-4)– 32 rev. power (EMCP 4.3 and AGC-4)– 40 loss of excitation (AGC-4 impedance based)– 50/51 Inst. and time overcurrent (GCB trip unit and AGC-4)– 47 Negative Voltage Sequence (AGC-4)– 46 Negative Sequence Current (AGC-4)– 27/59 phase under/over voltage (EMCP 4.3 and AGC-4)– 81O/U under/over frequency (EMCP 4.3 and AGC-4) Modes of Operation • Provides for single unit stand-alone operation, island mode paralleling and load sharing with other power modules, and single unit-to-utility mode paralleling for base load control (with open transition between paralleling modes) • Island mode paralleling features:– AGC-4 control allows single unit to connect to a dead bus– Auto synchronization (voltage & phase matching)– Load sharing (kW) analog signal (like units & legacy compatible)– Load sharing (kVAR) analog signal (like units only) • Utility mode paralleling features:– Auto synchronization (voltage & phase matching)– Base-load control (selectable: programmable set- point or potentiometer adjust)– Soft load/unload (programmable, shared set-point)– Power Factor control (programmable set-point) 

Contact Us for a Quote

Atlantic Power & Equipment Interest Form

Please submit your contact information below and we will be in touch shortly. Thank you!

SIGN UP TODAY!

Get free, premium access to our latest deals, product announcements, expert-written guides, and so much more - delivered right in your inbox.

Logo

Worldwide Provider of Power Generation Systems & Solutions

© 2026 by Atlantic Power & Equipment Co. 

Website Design by KayBee
 

Atlantic City, New Jersey

  • Facebook
bottom of page