Caterpillar XQ2280 Power Module (NEW FULL WARRANTY)
Caterpillar Introduces Cat® XQ2280 Power Module, the Industry’s First Large-Scale, Single-Engine Mobile Power Module Certified to U.S. EPA Tier 4 Final Emission Standards
Now available for 60-Hz applications from Cat dealers throughout North America, the Cat XQ2280 power module provides up to 2 MW of standby power or 1825 kW of prime power. Its essential components are all packaged in a weather-resistant 48-foot container that streamlines transport and deployment while offering exceptional sound attenuation.
The Cat XQ2280 is ideal for data centers, healthcare facilities, municipal infrastructure, wastewater treatment plants and other utilities, mining and quarry sites, and other large-scale applications.
“As the need grows for temporary power solutions that can support operations at an enterprise scale, the Cat XQ2280 offers superior prime and standby power performance in a complete, easy-to-operate package that meets North America’s most stringent emission standards.” said Tom Caldwell, global general manager for electric power rental solutions at Caterpillar.
Optimal Performance for Rental Customers
Powered by the field-proven Cat 3516C engine, the Cat XQ2280 power module offers numerous features making it ideal for rental applications. It is equipped with the EMCP 4.4 digital control panel, which provides all generator set controls and system indicators in a single, easy-to-access interface, as well as a programmable logic controller (PLC) functionality that improves reliability and flexibility for accommodating changes in processes or application requirements.
The Cat XQ2280 power module is highly mobile for simplified site logistics, featuring external fuel and diesel exhaust fuel (DEF) fill ports positioned on the same side of the module for convenient single-side access. A new externally mounted touch-screen human machine interface provides a safe and convenient way for monitoring operating status and performing common tasks without entering the unit, such as starting or stopping the machine.
It is equipped with Cat Connect technology to remotely track and manage the generator set and improve operational efficiency. The telematics send real-time information on fuel level, diesel exhaust fluid (DEF) level, battery voltage, and run status. Connected assets support peak operation with timely insights that help customers better control costs, improve performance and reduce risks.
The Cat XQ2280 power module is designed with a dual-wall, 1,050-gallon fuel tank that enables up to 10 hours of prime operation, and an optional cold-weather package is available for operation in extreme weather conditions. It can use up to 100% hydrotreated vegetable oil (HVO), a renewable fuel that can help customers reduce the impact of their operations on the environment.
Additionally, the Cat XQ2280 reduces sound levels to 81 dB(A) at 7 meters per SAEJ1074, when measured at 75% prime load and 75% fan speed.
Fully designed and tested by Caterpillar, the Cat XQ2280 uses proven technologies seamlessly integrated to enable simple, reliable operation. All Cat mobile generator sets are available through the worldwide Cat dealer network. Cat dealers work 24 hours a day, seven days a week to assist with emergency rental needs and provide a comprehensive range of maintenance and services.
XQ2280 Technical Data
Frequency
Voltage
Standby
kW (kVA)
Prime kW (kVA)
Speed rpm
60 Hz
480/277V
2000 (2500)
1825 (2280)
1800
Cat® 3516C Tier 4 Diesel Engine
Metric
Imperial (English)
Number of Cylinders
16
Bore
170 mm
6.7 in
Stroke
215 mm
8.5 in
Displacement
78.08 L
4764 in3
Aspiration
Turbocharged Aftercooled
Compression Ratio
14.7:1
Engine Speed
1800 rpm
Fuel system
EUI
Governor Type
ADEM™ A4 Control System
Fuel
Requires Ultra Low Sulfur Diesel (ULSD)
Features & Benefits
Fuel/Emissions Strategy
• Meets U.S. EPA Tier 4 Final emission standards and CARB certified for non-road mobile applications at all 60 Hz ratings
Design Criteria
• Conforms to ISO 8528 “G2” load acceptance requirements
Single-source Supplier
- Package is factory designed and production tested
- Manufactured in ISO 9001:2015 facility
Cat® 3516C Diesel Engine
- Turbocharged-aftercooled, four-stroke diesel engine
- Reliable, rugged, durable, fuel efficient
- Combines consistent performance and excellent fuel economy with minimum weight
- Electronic ADEM A4 engine control
- Electronic differential pressure monitoring of filters
Cat Clean Emissions Modules (CEM)
- Aftertreatment module consists of Caterpillar
Diesel Oxidation Catalyst (DOC), Selective
Catalytic Reduction (SCR), and Ammonia
Oxidation Catalyst (AMOX)
- Removable insulation blankets to maintain exhaust temperatures for aftertreatment health
- Integrated sound attenuation chambers
- Closed-loop NOx control
Pump Electronic Tank Unit (PETU)
- Stainless steel DEF tank with on-tank fill and remote fill
- Equipped with dosing pump and level sensor to display the Diesel Exhaust Fluid (DEF) level in EMCP & HMI panel
- Integrated heating elements and filter
Cat SR5 Series Generator
- Designed to match the performance and output characteristics of Cat diesel engines
- Class H insulation operating at Class F temperature for extended life
- Coastal insulation protection and anticondensation space heaters for extended life and increased reliability
Cat EMCP 4.4 Control Panel
- Fully featured power metering, protective relaying engine/generator control and monitoring
- Simple user-friendly interface and navigation
HMI Exterior Controls
• Allows for external operation, including start / stop, after EMCP is placed in Auto
Cat Integrated Voltage Regulator (Cat IVR)
- Three-phase sensing
- Adjustable volts-per-hertz regulation
- Provides precise control, excellent block loading, and constant voltage in the normal operating range
Sound Attenuated Container
- Provides ease of transportation and protection
- Sound level is 81 dB(A) at 7 meters per SAE J1074 measured at 75% prime load and 75% fan speed
Reduced Environmental Impact
- 110% spill containment of onboard engine compartment fluids
- Variable frequency fan drive with smart fan control to prevent overcooling in low ambient temperature conditions and reduced sound at partial loads
Asset Monitoring and Management
- Equipped with Cat Connect PLE743 hardware
- Provides cellular connectivity for remote asset monitoring
Factory-Installed Standard Equipment
Cat 3516C Diesel Engine
- Turbocharged, air-to-water aftercooler
- Electronic ADEM A4 engine control
Air Inlet
- Heavy-duty air element, canister type
Aftertreatment
• Air-assisted DEF delivery ensures proper mixing with exhaust gases and optimal NOx reduction
DEF System
- 78-gallon stainless steel DEF tank provides capacity to meet or exceed fuel tank runtime
@ 75% prime
- Electrically heated lines from tank to CEM
- Equipped with electric heaters to prevent freezing when genset is running or connected to shore power
- Equipped with low and critically low-level alarms with a
- critically low shutdown
Factory-Installed Standard Equipment
Containerized Module
- 48' ISO high cube container